Dependence of ultrasonic contact impedance hardness on Young’s modulus of elasticity of creep-resistant steels

Authors

  • Michal Junek CTU in Prague, Faculty of Mechanical Engineering, Department of Materials Engineering, Prague, Czech Republic
  • Jiri Janovec CTU in Prague, Faculty of Mechanical Engineering, Department of Materials Engineering, Prague, Czech Republic
  • Petr Duchacek CTU in Prague, Faculty of Mechanical Engineering, Department of Materials Engineering, Prague, Czech Republic

DOI:

https://doi.org/10.21014/acta_imeko.v6i1.325

Abstract

The paper deals with the hardness measurements by mobile UCI hardness testers as a means of determining the residual operation life of power unit components. It aims to answer questions regarding the level of dependence of UCI hardness on Young's modulus of creep-resistant steels and determining the conditions of a UCI hardness tester calibration. The experimental part describes comparative measurements of hardness values obtained using stationary hardness testers and UCI hardness testers.

Downloads

Published

2017-04-25

Issue

Section

Research Papers