Calibration and metrological characterization of a wearable inertial device for jump height measurement in professional athletes

Authors

  • Luna Panni Dept. of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, v. Brecce Bianche snc, 60131 Ancona, Italy
  • Gloria Cosoli Dept. of Theoretical and Applied Sciences, eCampus University, v. Isimbardi 10, 22060 Novedrate, Italy http://orcid.org/0000-0001-7982-208X
  • Marco Arnesano Dept. of Theoretical and Applied Sciences, eCampus University, v. Isimbardi 10, 22060 Novedrate, Italy
  • Lorenzo Scalise Dept. of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, v. Brecce Bianche snc, 60131 Ancona, Italy

DOI:

https://doi.org/10.21014/actaimeko.v15i4.2329

Keywords:

jump height estimation, sport performance, wearable sensors, IMU, metrological characterization

Abstract

The countermovement jump is a recognized indicator of neuromuscular function and lower-limb explosive power, with applications in both sport performance assessment and rehabilitation. Gold-standard measurement systems, such as force platforms and motion capture, are accurate but are limited by high costs, lack of portability, and constrained applicability in field settings. Wearable inertial measurement units (IMUs) have emerged as a promising alternative, enabling the unobtrusive monitoring of athletes in real-world conditions; however, their reliability strongly depends on metrological performance. This study presents an application-oriented metrological characterization of a commercially available inertial device (K-AI, K-Sport, Italy) for jump height estimation in professional athletes. A total of 31 elite basketball and volleyball players performed sport-specific jumps at varying intensities and distances. Jump height estimated by the IMU using the flight-time method was compared against a non-invasive markerless video-based reference system (MediaPipe Pose). Results revealed a systematic underestimation by the IMU (mean residual: –0.12 m; 95 % CI: [–0.20, –0.03] m), although a strong linear correlation with the reference was observed (ρ = 0.95). A calibration function was derived to correct systematic bias, and the combined expanded uncertainty (k = 2) was quantified at 0.10 m. The study demonstrates that properly calibrating the K-AI device is a practical, field-deployable solution that supports reliable athlete monitoring in real-world environments.

Author Biography

Gloria Cosoli, Dept. of Theoretical and Applied Sciences, eCampus University, v. Isimbardi 10, 22060 Novedrate, Italy

G. Cosoli was born in Chiaravalle (AN) in 1989. She received the M.S. degree in electronic engineering (cum laude) from the Università Politecnica delle Marche (UNIVPM) in 2013 and the Ph.D. degree in mechanical engineering from the same university in 2017.
From 2016 to date, she has been a Postdoctoral Research Fellow with the Department of Industrial Engineering and Mathematical Sciences (DIISM) of UNIVPM. 

Downloads

Published

2026-11-25

Issue

Section

Research Papers